Friday, May 31, 2019

PIV Measurement of Fluid Flow Inside a Human Uterus Model for Cryoablation :: essays research papers

PIV MEASUREMENT OF FLUID FLOW INSIDE A HUMAN UTERUS MODEL FOR CRYOABLATIONXiaolong Luo1, Jim S.J. Chen1, Marla Wolfson2, Charles Philips2, Thomas Shaffer21Department of Mechanical Engineering, Temple University2Temple University School of medical specialtyAbstract A new technique has been proposed that allows cryoablation to be achieved on the entire inner surface of the endometrium by circulating very cold perfluorochemical (PFC) silver intimate the human uterus. To understand the PFC flow field inside the uterus during cryoablation, a uterus model was constructed a fluid delivery system including the fluid delivery probe was designed and built to simulate the PFC flow during cryosurgery. With particle image velocimetry (PIV), the fluid flow inside the uterus was investigated at manner temperature to display a 2-D whole field velocity contour and vector plot.Keywords PIV, cryoablation, PFC, endometriumI. INTRODUCTIONMenorrhagia is medically defined as excessive bleeding at men ses, in duration or amount. A frequent cause of menorrhagia is uterine fibroid growth. Traditionally, hysterectomy is the main treatment for menorrhagia. Several cryosurgery methods such as localized cryoprobes 1 and pilot ablation 2 have been developed as alternatives to hysterectomy to treat the dysfunction of the endometrium. However, these are localized techniques and sometimes there is still proliferation of the endometrium. A new technique is proposed that allows cryoablation to be achieved on the entire inner surface of the endometrium using a PFC fluid 3. The objective of this project is to develop an efficient treatment method for aberrant uterine bleeding by freezing the endometrium. It has been shown that a temperature of 30 &61616C is required for destroy tissue necrosis 4. The heat transfer process during cryoablation was investigated through an experiment and numerically (1-D) with good agreement 5, in which a uniform fluid temperature boundary condition was used in the 1-D finite difference method to conciliate the temperature history in the human uteri of eight patients. This assumed that the fluid flow inside the uterus is uniform, repeatable and controllable. During the experiments it was found that the temperature difference at the inlet and venthole of the insertion probe varied from 10C to 50C. Inconsistent fluid temperatures may be caused by inadequate circulation of PFC liquid, i.e., recirculation within the uterus. The oddment of this study is to understand the flow field inside the uterus cavity during cryoablation so that the desired flow field and uniform temperature field can be obtained, thus proposing an optimal insertion probe design so that minimum PFC liquid and surgery time is used.

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.